Building with temperature-controlled storage, ventilation control and separate lighting systems.
Features
- 20 x 24 m portal frame shed in juniper green cladding, 10 m eaves, spray-foamed roof and precast concrete panels inside
- Insulated 6 m sectional roller door with header box and switch, plus working personnel and plant room doors
- Rear plant room with mezzanine and stairs, three full-height evaporator units, insulated pipework, isolators, distribution boards and a walk-in MCC panel with opening doors, including drives, PLC, contactors, breakers and wiring inside
- Overhead air ducts with six spinning circulation fans, three outside condensers, weather louvres, temperature sensors and cabling, rodent bait stations and plenty of small details
Ventilation control
- Open the fan control box in the plant room and switch FAN 1, 2 and 3 groups on or off
- Fans spin up and coast down realistically, with sound and flashing run lamps while starting
- Large control screen showing the air flow, evaporators, condensers, crop probe temperatures and trends
- Fans are off when first bought
Object storage (shop option)
- Store crop boxes and pallets: drop them in the worn yellow LOADING BAY in front of the door
- Boxes stack 8 high inside, filling from the back of the store forward, with a clear walkway to the plant room
- Unloaded boxes come out two high in the UNLOAD AREA on the apron
- Choose “No” in the shop for a plain store without object storage, cheaper
Lights
- Separate switches for the store lights, plant room lights and an outside yard spotlight
Specifications
- Price: 185,000
- Category: Sheds / Storage
Changelog
- V1.0.2.0
- Fixed: the loading bay markings prompt now shows when standing by either yellow bollard at the roller door
- Ceiling lamps now hang from the roof instead of floating below it
- Circulation fans hung on galvanised drop rods with ceiling plates
- Air ducts on proper trapeze hangers, all hanger rods reach the rafters
- Gutters are now open channels with stop ends and outlets, moved in under the roof edge; downpipes connect into them
- New click spot at the yellow bollards to remove or show the loading bay markings
- Fixed flickering textures on the door frames and the long walls / gable ends
- Fixed darker patches on the wall cladding, inverted sheet faces
- Light switches now stand upright on the wall facing the right way; plant room switch moved to the handle side of the door
- Yard light changed to the TerraLED 20W spotlight
- Fans spin up and coast down with sound and flashing run lamp; fans are off when bought
- Fan control box door now opens correctly
- Removed the hazard floor mat in front of the MCC panel
- Added O&M manual tube next to the fan control box